![]() 61658 R08, Printed in the USA 04/08 PARTS & ACCESSORIES R.W. Beckett Corporation Mail: P.O. Box 1289, Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876) ● FAX: (440)327-1064 R.W. Shirley collins. Beckett Canada Ltd. Unit 3 - 430 Laird Road, Guelph, Ontario, Canada N1G 3X7 ● Phone: 800-665-6972 ● FAX: (519)763-5656 www.beckettcorp.com Priming The Pump Initiate a call for heat. When the burner starts, press and hold the reset button for 15 seconds until the yellow light turns on. Release the button. The yellow light will turn off and the burner will start again. At burner start up, click the reset button while the igniter is still on to enter Pump Prime mode. The yellow light will turn on. Bleed the pump until all froth and bubbles are purged. If necessary, repeat steps 4 and 5 until the pump is fully primed and the oil is free of bubbles. When fi nished, hold the reset button or remove the call for heat to exit Pump Prime mode and return to Standby. Operation Sequence of Operation Yellow LED Flashes Cad Cell Resistance 1 Normal (0 - 400 ohms) 2 Normal (400 - 800 ohms) 3 Normal (800 - 1600 ohms) 4 Limited (1600 ohms - Lockout) Resetting From Restricted Lockout If the control locks out three times without a satisfi ed call for heat or fails the motor relay check, the Lockout becomes restricted in order to prevent repetitious resetting by the homeowner. To reset, hold the button down for 15 seconds until the red light turns off and the yellow LED turns on. Disable Function Any time the burner is running, press and hold the reset button to disable the burner. Please consider upgrading to a more recent version of Internet Explorer, or trying another browser such as Firefox, Safari, or Google Chrome. Jive will not function with this version of Internet Explorer. Adobe premiere 7 download. In order to provide the best platform for continued innovation, Jive no longer supports Internet Explorer 7. Attention, Internet Explorer User Announcement: Jive has discontinued support for Internet Explorer 7 and below. The burner will remain off as long as the button is held. Cad Cell Resistance Indicator During the burner Run state, click the reset button to check the cad cell fl ame resistance range. The yellow light will fl ash 1 to 4 times depending on the amount of light detected by the cad cell. See the table below: Cross-Reference Chart Beckett GeniSys Control Part No. Lockout Time Valve-on delay time 2 Motor-off delay time 2 Replaces Honeywell: Replaces Carlin: 7505A 0000 15 sec - - R7184A, R8184G 48245, 0, 50200 1 7505B 1500 15 sec 15 sec - R7184B - 7505P 1515 15 sec 15 sec 15 sec R7184P, R7184U 1 60200 1 7505P 1530 15 sec 15 sec 30 sec R7184P, R7184U 1 60200 1 7505P 152M 15 sec 15 sec 2 min R7184P, R7184U 1 60200 1 1) Beckett snap-in alarm module required for direct replacement of the control. Nfpa 12 standard on carbon dioxide extinguishing systems 2011 edition pdf. Popular Beckett questions, problems & fixes. Find expert solutions to common issues, DIY guides, repair tips & user manuals for all Beckett products. ![]() 2) Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-in programming display. Other factory set timings are available. Contact Beckett for alternate timings. ![]() Beckett Cb151ul Condensate Pump ManualElectrical Ratings Inputs Voltage: 102 to 132 Vac Current: 150 mA plus burner motor, igniter, and valve loads Frequency: 60 Hz Outputs Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA) Note – Reduce motor FLA rating by igniter current Igniter: 120 Vac, 3 A @ 0.7 PF min Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min Thermostat Anticipator Current: 0.1 A (If applicable) Thermostat Voltage: 24 Vac (If applicable) Application Ratings Oil Burner Input.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |